Water Detection Sensor Module
Water detection sensor is used to detect water leak, water level or rains. This is obtained by having a series of parallel wires exposed traces. The sensor traces have a weak pull-up resistor of 1 MΩ. The resistor will pull the sensor trace value high until a drop of water shorts the sensor trace to the grounded trace.
The analog signal output can be read directly to arduino
- Delivery & Return
Delivery
Store delivery FREE
1-3 working days
Home or collection point from £35.00 FREE
On all your orders for home or collection point delivery
Returns
Return
We will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period).
Returns in store FREE
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
EGP40.00
Specifications
- Operating voltage: 5V
- Operating current: less than 20mA
- Sensor Type: Analog
- Detection Area: 40mmx16mm
- Product Dimensions: 62mmx20mmx8mm
- Motors & Robotics
- Microcontrollers
- CNC | Stepper | Mechanical | 3D Printer
- Transistor & Mosfet
- Wirless
- Resistors | Capacitors | Diodes
- Data Convert | Modules
- Cables | Wires | Shrink
- Battery | Supply | Relay | Solar
- Crystals | Oscillators
- Display | Audio | Printer
- Soldering
- Joystick | Keypad | Switch
- LED | Laser | Heater | Fan
- Connectors & Sockets
- Sensors
- PCB | Boards
- Processing Boards
- ICs
Related Products
MQ-9 gas sensor has high sensitity to Carbon Monoxide, Methane and LPG. The sensor could be used to detect different gases contains CO and combustible gases, it is with low cost and suitable for different application.
The sensitivity of the sensor can be adjusted by using the potentiometer.
TDS (Total Dissolved Solids) measures how many milligrams of soluble solids dissolved in one liter of water. The measure is expressed in PPM (part per million). In general, the higher the TDS value, the more soluble solids dissolved in water, and the less clean the water is. Therefore, the TDS value can be used as one of the references for reflecting the cleanliness of water.
Thanks to this product, it becomes possible to create your own measurement, collection and data transmission system. It is even possible to use this information to automate water treatment cycles. The TDS probe is waterproof; it can be immersed in water for long time measurement. However, the signal transmitter board is not waterproof.
The MQ7 is a simple-to-use Carbon Monoxide (CO) sensor suitable for sensing CO concentrations in the air. It can detect CO-gas concentrations anywhere from 20 to 2000ppm. MQ7 is a high sensitivity to carbon monoxide and stable and long-life span.
This sensor has a high sensitivity and fast response time. It is suitable for sensing hydrogen concentrations in the air. The MQ-8 can detect hydrogen gas concentrations anywhere from 100-10000ppm.
The sensor can output an analog or digital signal. The sensitivity can be adjusted by the potentiometer.
They are used in gas leakage detecting equipments in home and industry applications.
Water flow sensor consists of a plastic valve body, a water rotor, and a hall-effect sensor. When water flows through the rotor, rotor rolls. Its speed changes with different rate of flow. The hall-effect sensor outputs the corresponding pulse Signal. Can be used with ardduino
A soil moisture sensor can read the amount of moisture present in the soil surrounding it. It is ideal for monitoring garden, or your plant’s water level. This is a must have tool for a connected garden.
This new type capacitive soil humidity sensor differs from other resistive sensors, adopting capacitive sensing principle to detect soil humidity. Since the circuit is not exposed at the detected end, the corrosion problem of sensor is avoided, increasing the sensor operating life and measurments accuracy.
The built-in chip supports 3.3~5.5V working environment, Arduino, ESP32, micro:bit and controller. As to mini PC, you need an ADC module (analog signals are converted into signals).
This is an industrial grade soil and water PH and temperature sensor. The new generation Ph sensor can measure pH and temperature level in both soil and water as well. Soil and water pH is a measure of the acidity or alkalinity of the soil or water. Soils (or water) can be classified according to their pH value where 6.5 to 7.5 is neutral soil (Ideal soil for growing plants), over 7.5is alkaline and less than 6.5 is acidic. The sensor has RS 485 serial interface with 2-meter cable which can be extended to 1000 meter without affecting measured data quality, thanks to RS 485 long distance serial communication interface. It can be integrated with GPRS/4G/WIFI/LORA wireless module.
This is 4 in 1 water and soil sensor. The new generation sensor can be used for Ec, moisture, salinity and temperature measurements in both water and soil media as well. This sensor is a high quality Anti-corrosion, stainless steel industrial standard sensor that can measure soil and water EC (conductivity), soil and water moisture contents, Salinity and temperature. This sensor enjoys high precision, long life and high stability in measurements. The sensor has RS 485 serial interface with 2-meter cable which can be extended to 1000 meter without affecting measured data quality, thanks to RS 485 long distance serial communication interface. It can be integrated with GPRS/4G/WIFI/LORA wireless module.
The soil nutrient content can be easily measured using NPK Soil Sensor. Measurement of soil content N (nitrogen), P (phosphorus), and K (potassium) is necessary to determine how much additional nutrient content is to be added to soil to increase crop fertility.
The soil fertility is detected using NPK sensors. A major component of soil fertilizer is nitrogen, phosphorus, and potassium. The knowledge of the soil nutrient concentration can help us to learn about nutritional deficiency or abundance in soils used to endorse plant production.
This Soil NPK sensor is a low cost, quick responsive, high precision & portable Sensor that works with Modbus RS485. The advantage of this sensor over a traditional detection method is that it gives very fast measurement & data are highly accurate. All you need is to insert its probe in soil and get the reading using your MCU (Arduino, Tiva C, Raspberry, Personal computer).
This 4 in 1 water quality sensor is a high quality industrial standard sensor that can measure EC (conductivity), TDS (total dissolved solids), Salinity and water temperature. This sensor enjoy high precision, long life and high stability in measurements. The sensor has RS 485 serial interface with 2-meter cable which can be extended to 1000 meter without affecting measured data quality, thanks to RS 485 long distance serial communication interface. It can be integrated with GPRS/4G/WIFI/LORA wireless module. Â
Conductivity (EC) is a measure of the ability of water to pass an electric current; it is affected by the presence of dissolved solids such as chloride, nitrate and phosphate. Conductivity can be a very useful indicator that a discharge of some sort has entered a stream, or some other change has occurred. TDS Sensor detects the Total Dissolved Solids (TDS) levels in the water which can be used to indicate the water quality. The Salinity Sensor easily and precisely measures the total dissolved salt content in an aqueous solution.Â
This environmental sensor module is based on BME680 powerful environmental sensor. It can sense temperature, barometric pressure, humidity and VOC (volatile organic compound) gas of the surrounding environment.
You can monitor 4 environmental parameters simultaneously. All the measurements can be read through either I2C or SPI connection. With the BME680 you can monitor the air quality, surrounding air status, industrial pollution and controlled farming environment. Applications is not limited to weather forecasting, HVAC, home automation, fire protection systems, hazards storage area monitoring and medical space environment watching.
MQ-4 Sensor is highly sensitive to Methane – CH4.
Using a MQ sensor and detecting the gas is quite easy. You can either use the digital pin or the analog pin to accomplish this. Simply power the module with 5V and you should notice the power LED on the module to glow and when no gas is detected the output LED will remain turned off meaning the digital output pin will be 0V.