Dissolved Carbon Dioxide (CO2) Sensor (Water – Soil)
The measurement of dissolved carbon dioxide in water is one of the most important parameters in the field of aquaculture and in industry. So, this Carbon Dioxide (CO2) sensor probe allows the measurement of dissolved carbon dioxide directly in the water and soil. It can measure the Carbon Dioxide (CO2) concentration with high accuracy with large measuring range up to 5000 ppm. The CO2 probe has an analog both RS485 and TTL output for connection to your acquisition system.
You simply need to immerse the CO2 probe directly into the environment you want to monitor, whether it’s a fish farm pond, a lake, the open sea, in a bioreactor, or a manufacturing process. The sensor then provides a continuous measurement of the partial pressure of dissolved CO2 in water.
- Delivery & Return
Delivery
Store delivery FREE
1-3 working days
Home or collection point from £35.00 FREE
On all your orders for home or collection point delivery
Returns
Return
We will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period).
Returns in store FREE
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed. Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.
- Ask a Question
EGP10,000.00
Specifications
- Operating Voltage: 5V.
- Output: RS485, UART TTL
- Measurement range: 0~5000 ppm
- Measurement accuracy: +/- 20 ppm
- Working Temperature: -20: + 60 ℃
- Temperature Measure range: -40~85℃
- Protection level: IP68
- Weight: 100g
- Connectors & Sockets
- Sensors
- PCB | Boards
- Processing Boards
- ICs
- Motors & Robotics
- Microcontrollers
- CNC | Stepper | Mechanical | 3D Printer
- Transistor & Mosfet
- Wirless
- Resistors | Capacitors | Diodes
- Data Convert | Modules
- Cables | Wires | Shrink
- Battery | Supply | Relay | Solar
- Crystals | Oscillators
- Display | Audio | Printer
- Soldering
- Joystick | Keypad | Switch
- LED | Laser | Heater | Fan
Related Products
Water detection sensor is used to detect water leak, water level or rains. This is obtained by having a series of parallel wires exposed traces. The sensor traces have a weak pull-up resistor of 1 MΩ. The resistor will pull the sensor trace value high until a drop of water shorts the sensor trace to the grounded trace.
The analog signal output can be read directly to arduino
The soil nutrient content can be easily measured using NPK Soil Sensor. Measurement of soil content N (nitrogen), P (phosphorus), and K (potassium) is necessary to determine how much additional nutrient content is to be added to soil to increase crop fertility.
The soil fertility is detected using NPK sensors. A major component of soil fertilizer is nitrogen, phosphorus, and potassium. The knowledge of the soil nutrient concentration can help us to learn about nutritional deficiency or abundance in soils used to endorse plant production.
This Soil NPK sensor is a low cost, quick responsive, high precision & portable Sensor that works with Modbus RS485. The advantage of this sensor over a traditional detection method is that it gives very fast measurement & data are highly accurate. All you need is to insert its probe in soil and get the reading using your MCU (Arduino, Tiva C, Raspberry, Personal computer).
The MQ-135 gas sensor senses gases like ammonia nitrogen, oxygen, alcohols, aromatic compounds, sulfide, and smoke.
The boost converter of the chip MQ-3 gas sensor is PT1301. The operating voltage of this gas sensor is from 2.5V to 5.0V. The MQ-3 gas sensor has a lower conductivity to clean the air as a gas sensing material. In the atmosphere, we can find polluting gases, but the conductivity of the gas sensor increases as the concentration of polluting gas increases. MQ-135 gas sensor can be implemented to detect the smoke, benzene, steam, and other harmful gases. It has the potential to detect different harmful gases. The MQ-135 gas sensor is a low co st to purchase.
This is an economical oxygen sensor to measure oxygen concentration (percentage) and gas Volumetric Flow Rate. The sensor measures the gas temperature also. The Oxygen sensor in home and medical oxygen generator, PSA oxygen generator, anesthesia monitors, medical ventilator, breathing equipment, oxygen analyzer, hospitals, laboratories, combustion and environmental applications.
The Oxygen sensor output oxygen concentration, flow rate and temperature digital data through serial UART. This make it it easy to receive data and handle it using arduio, microcontroller or pc interface.
The oxygen sensor uses the ultrasonic velocity difference between upstream and downstream to measure oxygen concentration. This cutting edge ultrasonic technology enables small size, stable, high accuracy, low cost sensor module, long life span (>5 years). In addition, there is no need foe routine calibration.
Water flow sensor consists of a plastic valve body, a water rotor, and a hall-effect sensor. When water flows through the rotor, rotor rolls. Its speed changes with different rate of flow. The hall-effect sensor outputs the corresponding pulse Signal. Can be used with ardduino
This sensor has a high sensitivity and fast response time. It is suitable for sensing hydrogen concentrations in the air. The MQ-8 can detect hydrogen gas concentrations anywhere from 100-10000ppm.
The sensor can output an analog or digital signal. The sensitivity can be adjusted by the potentiometer.
They are used in gas leakage detecting equipments in home and industry applications.
This water PH sensor is high quality, high precession, industrial standard water PH sensor. It is designed to be used in industrial applications such as water treatment facilities, rivers, lakes, peverage industry. The PH sensor equipped with 2 meter low noise cable. It is designed for low power consumption, long life and high measurement stability,
PH is a measure of acidity or alkalinity of a solution. It is commonly used to measure the quality of the water or for water monitoring. The pH scale ranges from 0 to 14.
This smoke sensor module with MQ2 Smoke sensor have both digital and analog outputs , you also can adjust the sensitivity with the potentioneter.
TDS (Total Dissolved Solids) measures how many milligrams of soluble solids dissolved in one liter of water. The measure is expressed in PPM (part per million). In general, the higher the TDS value, the more soluble solids dissolved in water, and the less clean the water is. Therefore, the TDS value can be used as one of the references for reflecting the cleanliness of water.
Thanks to this product, it becomes possible to create your own measurement, collection and data transmission system. It is even possible to use this information to automate water treatment cycles. The TDS probe is waterproof; it can be immersed in water for long time measurement. However, the signal transmitter board is not waterproof.
This is an industrial grade soil and water PH and temperature sensor. The new generation Ph sensor can measure pH and temperature level in both soil and water as well. Soil and water pH is a measure of the acidity or alkalinity of the soil or water. Soils (or water) can be classified according to their pH value where 6.5 to 7.5 is neutral soil (Ideal soil for growing plants), over 7.5is alkaline and less than 6.5 is acidic. The sensor has RS 485 serial interface with 2-meter cable which can be extended to 1000 meter without affecting measured data quality, thanks to RS 485 long distance serial communication interface. It can be integrated with GPRS/4G/WIFI/LORA wireless module.
MQ-9 gas sensor has high sensitity to Carbon Monoxide, Methane and LPG. The sensor could be used to detect different gases contains CO and combustible gases, it is with low cost and suitable for different application.
The sensitivity of the sensor can be adjusted by using the potentiometer.
MQ-4 Sensor is highly sensitive to Methane – CH4.
Using a MQ sensor and detecting the gas is quite easy. You can either use the digital pin or the analog pin to accomplish this. Simply power the module with 5V and you should notice the power LED on the module to glow and when no gas is detected the output LED will remain turned off meaning the digital output pin will be 0V.